Newest papers

An Open Reliability Atlas of Sensitivity and Failure Modes in the Pulse Physiology Engine

Santino Nanini, Arnaud Wiedemann, Yassir Mamouni, Cyril Schweitzer, Philippe A. Jouvet, Michael Sauthier · 2026 · arXiv (Cornell University)

DOI: 10.48550/arxiv.2610.28517 · cited by 0 works (OpenAlex) · open-access PDF

Indonesian

Pulse adalah simulator fisiologi dewasa open-source yang secara aktif dipelihara, namun pemeliharanya tidak melaporkan analisis sensitivitas formal dari input operasionalnya. Kami menyajikan atlas keandalan terbuka pertama di seluruh kemasan perawatan kritisnya: Morris elementary-effects sampling dari tujuh input, empat skenario keparahan, tubuh laki-laki dan perempuan (1,280 simulasi). Sensitivitas terganggu: tiga input membawa median 93% dari total setiap output. Sebuah klasifikator empat bendera mengungkapkan mode kegagalan: dua operator-aktif, satu sex-stratified. Tidal-volume oscillation (20.6% dari run) konsisten dengan dysynchrony pasien-ventilator; mengunci trigger VCAC ke -2 cmH2O menghancurkan variabilitas itu. Pada FiO2 = 1.0, hyperoxia trans

Machine translation (Meta M2M100); the English original follows.

Abstract

Pulse is an actively maintained open-source adult-physiology simulator, yet its maintainers report no formal sensitivity analysis of its operational inputs. We present the first open reliability atlas across its critical-care envelope: Morris elementary-effects sampling of seven inputs, four severity scenarios, male and female bodies (1,280 simulations). Sensitivity is skewed: three inputs carry a median 93% of each output's total. A four-flag classifier reveals failure modes: two operator-actionable, one sex-stratified. Tidal-volume oscillation (20.6% of runs) is consistent with patient-ventilator dyssynchrony; locking the VC-AC trigger to -2 cmH2O collapses that variability. At FiO2 = 1.0, transient hyperoxia makes 120-second runs underestimate plateau PaO2; 300-second healthy-lung reruns give a median 643 mmHg. Solver divergence was all-male in an input-extreme regime (20/1,280); reducing the male blood-volume baseline to the 4,082 mL floor eliminated it. Runs and flags are released openly, showing users which regions need checking before training on Pulse output.

Read in: English · Spanish · Chinese · Hindi · Arabic · Portuguese · French · German · Japanese · Russian · Korean · Indonesian · Vietnamese

Topics: Computer science, Sensitivity (control systems), Atlas (anatomy), Pulse (music), Reliability (semiconductor), Acoustics

Is this paper real? This page was built from OpenAlex and arXiv records, not generated. Software can verify any reference in one call: GET https://store.agentexchange.work/gw/papers/verify?title=...&year=... (0.003 USD), fetch this record as JSON with /gw/papers/paper?id=2610.28517, or list what it cites with /gw/papers/references?id=.... Pay per call in USDC (x402) or with a 19 USD card key for 1,000 calls. Catalogue · llms.txt

Sources: OpenAlex (CC0), arXiv, Crossref. Agent Exchange