Newest papers

An Open Reliability Atlas of Sensitivity and Failure Modes in the Pulse Physiology Engine

Santino Nanini, Arnaud Wiedemann, Yassir Mamouni, Cyril Schweitzer, Philippe A. Jouvet, Michael Sauthier · 2026 · arXiv (Cornell University)

DOI: 10.48550/arxiv.2610.28517 · cited by 0 works (OpenAlex) · open-access PDF

Korean

Pulse는 활발하게 유지되는 오픈 소스 성인 생리학 시뮬레이터이지만 유지 관리자는 운영 입력에 대한 공식적인 민감성 분석을보고하지 않습니다. 우리는 중요한 보살핌 포장에 걸쳐 첫 번째 오픈 신뢰성 아틀라스를 제시합니다 : 모리스 원본 효과는 7 개의 입력, 4 개의 심각성 시나리오, 남성과 여성 신체 (1,280 시뮬레이션)를 샘플링합니다. 민감성은 왜곡됩니다 : 3 개의 입력은 각 출력의 총 중간 93%를 가져옵니다. 4 개의 깃발 분류기는 실패 모드를 밝힙니다 : 두 개의 운영자-행동, 하나의 성-층화. Tidal 볼륨 진동 (20.6 %의 실행)은 환자 - 밸런터 dysynchrony와

Machine translation (Meta M2M100); the English original follows.

Abstract

Pulse is an actively maintained open-source adult-physiology simulator, yet its maintainers report no formal sensitivity analysis of its operational inputs. We present the first open reliability atlas across its critical-care envelope: Morris elementary-effects sampling of seven inputs, four severity scenarios, male and female bodies (1,280 simulations). Sensitivity is skewed: three inputs carry a median 93% of each output's total. A four-flag classifier reveals failure modes: two operator-actionable, one sex-stratified. Tidal-volume oscillation (20.6% of runs) is consistent with patient-ventilator dyssynchrony; locking the VC-AC trigger to -2 cmH2O collapses that variability. At FiO2 = 1.0, transient hyperoxia makes 120-second runs underestimate plateau PaO2; 300-second healthy-lung reruns give a median 643 mmHg. Solver divergence was all-male in an input-extreme regime (20/1,280); reducing the male blood-volume baseline to the 4,082 mL floor eliminated it. Runs and flags are released openly, showing users which regions need checking before training on Pulse output.

Read in: English · Spanish · Chinese · Hindi · Arabic · Portuguese · French · German · Japanese · Russian · Korean · Indonesian · Vietnamese

Topics: Computer science, Sensitivity (control systems), Atlas (anatomy), Pulse (music), Reliability (semiconductor), Acoustics

Is this paper real? This page was built from OpenAlex and arXiv records, not generated. Software can verify any reference in one call: GET https://store.agentexchange.work/gw/papers/verify?title=...&year=... (0.003 USD), fetch this record as JSON with /gw/papers/paper?id=2610.28517, or list what it cites with /gw/papers/references?id=.... Pay per call in USDC (x402) or with a 19 USD card key for 1,000 calls. Catalogue · llms.txt

Sources: OpenAlex (CC0), arXiv, Crossref. Agent Exchange